# TiDB 目标库Error 8048 isolation level 'SERIALIZABLE' is not supported
## 现象
目标库为 TiDB 时sling 数据迁移在每个 stream 的写入阶段失败:
```
writing to target database [mode: truncate]
created table `test_demo`.`crm_orders_tmp`
execution failed
Error 8048 (HY000): The isolation level 'SERIALIZABLE' is not supported.
Set tidb_skip_isolation_level_check=1 to skip this error
```
## 原因
TiDB 不支持 `SERIALIZABLE` 隔离级别TiDB 默认使用乐观锁/快照隔离。sling
在目标端开启事务时请求了 `SERIALIZABLE`TiDB 默认会直接报错拒绝。
TiDB 提供了兼容开关 `tidb_skip_isolation_level_check=1`:设置后跳过隔离级别
检查,按 TiDB 实际支持的级别执行。对"测试环境 → 本地 dev 库"的全量数据灌入
场景,这是安全的。
## 解决:连接参数
在 sling-ui 中编辑 TiDB 目标连接,在「连接参数」中加一行:
```
tidb_skip_isolation_level_check=1
```
### 工作原理
连接参数会被拼进连接 URL 的 query string例如
```
mysql://user:pass@tidb-host:4000/dbname?tidb_skip_isolation_level_check=1
```
sling 底层使用 go-sql-driver/mysql会把未识别的 DSN 参数作为 session 变量
在连接建立时执行 `SET <key>=<value>`(本项目内置的 `foreign_key_checks=0`
也是同一机制。Atlas 的连接 URL 同样会带上这些参数。
已实测验证:对普通 MySQL 设置该参数会报 `Error 1193: Unknown system
variable`,证明参数确实被 SET 为 session 变量TiDB 上该变量存在,即达到
预期效果。
## 备注
- 该参数只对 TiDB 有效,不要给普通 MySQL/MariaDB 连接设置。
- 若希望对整个 TiDB 实例生效(所有客户端),也可以在 TiDB 上执行
`SET GLOBAL tidb_skip_isolation_level_check=1;`,但用连接参数的方式
影响面最小,推荐。